Who's Online
There currently are 5004 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Downloaded the Service manual OK of the Technics Piano and have now repaired it and its going fine. Excellant; thank you for the fine servce. A.M
;
This site is working fine! Did buy a manual for SX-EX25L and after a while I could download it and fix the problem. Nice and easy!
;
Complete manual as pdf-file in very good quality. Very helpful and fast availability.
;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much
RR 640 CD / RR 670 CD
Abgleichvorschriften / Adjustment Procedures
2. Tuner
Messgeräte: Messsender, Wobbelsender, Oszilloskop, Frequenzzähler. Funktionsschalter: Radio Abgleich 1. AM-ZF Vorbereitung Wobbelsender 465kHz über Rahmenantenne in L506 (Ferritantenne) einkoppeln. Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW Drehkoanschlag: MW fu 515kHz, fo 1630kHz Messsendersignal über Rahmenantenne in L506 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW MW 558kHz, MW 1440kHz Messsendersignal über Rahmenantenne in L506 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW Drehkoanschlag: fo 292kHz Messsendersignal über Rahmenantenne in L507 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: LW LW 153kHz, LW 261kHz Messsendersignal über Rahmenantenne in L507 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: LW Drehkoanschlag: FM fu 87,35MHz, fo 108,25MHz Messsendersignal über 10nF an Messpunkt TP 1 / TP 2 (Masse) einkoppeln (fmod = 1kHz, �f = 22,5kHz, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: FM FM 88MHz, FM 106MHz Messsendersignal über 10nF an Messpunkt TP 1 / TP 2 (Masse) einkoppeln (fmod = 1kHz, �f = 22,5kHz, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: FM Messsendersignal keines IC501 zwischen Pin 1 und Pin 29 kurzschlie�en. Frequenzzähler an Messpunkt TP 5 (IC501 Pin 4). Abgleichvorgang Mit T501 auf Maximum einstellen.
2. MW Oszillator
fu (bei 515kHz) mit L504 auf Maximum einstellen. fo (bei 1630kHz) mit VCT501(B) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
3. MW Vorkreis
Bei 558kHz mit L506 (MW-Antennenspule) auf Maximum einstellen (verschieben). Bei 1440kHz mit VCT501(A) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
4. LW Oszillator
fo (bei 292kHz) mit TC502 auf Maximum einstellen.
5. LW Vorkreis
Bei 153kHz mit L507 (LW-Antennenspule) auf Maximum einstellen (verschieben). Bei 261kHz mit TC501 auf Maximum einstellen. Abgleich wechselseitig wiederholen.
6. FM Oszillator
fu (bei 87,35MHz) mit L503 auf Maximum einstellen. fo (bei 108,25MHz) mit VCT501(C) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
7. FM Vorkreis
Bei 88MHz mit L502 auf Maximum einstellen (verbiegen). Bei 106MHz mit VCT501(D) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
8. FM-MPX (Stereo)
Mit VR501 76kHz ± 100Hz einstellen.